Intro goes here
At 50-60% of the price of a new LA-306, you get a furnace that can be used for another 10-15 years with an all new control system, new furnace chamber internals and all new aircraft aluminum cooling section. We have a limited number of refurbished RTC LA-306 furnaces; this LAST ONE in stock and a few more in the warehouse available for reconditioning in our factory. Or we can recondition your LA-306 furnace with new digital controllers, electronics and lamps including replacement of any missing, damaged or necessary worn parts. These units are fully tested to original RTC factory specifications and are warranteed for one year from shipment. These furnaces are offered in conjunction with RGL Enterprises.
THERMAL PROCESSING | |
---|---|
Parameter | RTC LA-306 |
Load Station | 215 mm (8.5 inches) |
Entrance Isolation Baffle with Venturi Exhaust | 159 mm (6.25 inches) |
IR Heating Chamber, Zone 1 | 168 mm (6.6 inches) |
IR Heating Chamber Zone 2 | 363 mm (14.3 inches) |
IR Heating Chamber Zone 3 | 168 mm (6.6 inches) |
Transition Tunnel (with optional Venturi Exhaust) | 159 mm (6.25 inches) |
CACT Closed Atmosphere Cooling Chamber | 1015 cm (40 inches) |
Unload Station | 215 mm (8.5 inches) / with extension 9.78 mm (38.5 inches) |
NEWLY UPGRADED FROM SINGLE PHASE TO 3-PHASE
SPECIFICATIONS | |
---|---|
Parameter | LA-306 |
Process Gas | CDA, Nitrogen (-N), Forming Gas with premixed Hydrogen and Nitrogen (-FG) |
Control Zones | 3 zones |
Heating Chamber length | 700 mm (27.5 inches) |
Cooling Chamber | CACT – CDA or N2 convective and radiant cooling, exterior fan heat removal. |
Belt Speed | 25-500 mm/min (1-20 ipm) or 25-1000 mm/min (2-40) ipm (other speeds available) |
Conveyor Belt | BNV- low mass, stabilized Nichrome-V |
Belt Size, nominal width | 150 mm (6 in.) |
Exhaust | Improved venturi exhaust stacks to reduce process gas consumption. Number of stacks vary with process requirements. |
Temperature Capacity, max | 1000°C |
Electrical | Single phase design. All models include universal transformers which accommodate 208-240 Vac and 50/60 Hz frequency anywhere in the world, allowing furnace relocation without external equipment. IR lamp controls automatically keep IR spectrum constant. |
SPECIFICATIONS | |||
---|---|---|---|
Parameter | RTC LA-306 | Max Connected Power, Current | Operating Current @ 950C |
Single Phase Power (opt) Curve: Operating Current as a function of Temperature |
208 Vac, 1 ph, 50/60 Hz 220 Vac, 1 ph, 50/60 Hz 230 Vac, 1 ph, 50 Hz (EU) /60 Hz 240 Vac, 1 ph, 50/60 Hz |
14.0 kW, 67.3 14.3 kW, 65,2 14.6 kW, 63.7 15.0 kW, 62.3 |
39.0 A 38.0 A 36.9 A 36.0 A |
3-Phase Power Curve: Operating Current as a function of Temperature |
208 Vac, 3 ph, 50/60 Hz 220 Vac, 3 ph, 50/60 Hz 380 Vac, 3 ph, 50/60 Hz 415 Vac, 3 ph, 50/60 Hz |
14.0 kW, 38.9 14.3 kW, 37.7 14.3 kW, 37.7 15.0 kW, 36.0 |
26.0 A 25.0 A 25.0 A 23.0 A |
Parameter | Process Section | Typical (CDA exchange rate: 2x) 425 C operation, balanced flow |
Typical (N2 exch rate: 3x) 950 C, low O2, 25 sLpm excess flow |
Process Gas Supply | Gas 1 | 80 Lpm @ 5 bar (170 SCFH @ 70 psig) |
146 Lpm @ 5 bar (308 SCFH @ 70 psig) |
Gas 2 (Heating Chamber only) | see Gas 1 |
33 m3/hr @ 5 bar (69 CFM @ 70 psig) |
|
Process Gas Exhaust | Gas 1 + Gas 2 | 80 Lpm (170 SCFH) |
95 Lpm (202 SCFH) |
Enclosure Ventilation | Furnace Cabinet Fan (1) vent to room or facility exhaust system |
930 m3/hr @ 30°C (550 cfm @ 86°F) |
|
Control Cabinet Fans (2) (vents to room) |
360 m3/hr @ 30°C (212 cfm @ 86°F) |
||
Dimensions | Length | With 30-inch unload extension: 3.35 m (132 in.) | |
Width | 0.46 m (18 inches) | ||
Height | 1.64 m +/- 0.0254 (62.25 inches +/- 1.0) | ||
Adjustable Conveyor Height | 965 mm +/- 25.4 (38 inch +/- 1.0) | ||
Weight | 370 kg (800 LB) |
Standard features are listed on the Standard Features pages (see link below). Popular options include the following:
POPULAR OPTIONS | |||
---|---|---|---|
Code | Description | Code | Description |
NO | Nitrogen Operation, Dual Gas (N2 & FG) | OA | Oxygen Analyzer |
LT | Process Ready Light Tower | MA | Moisture Analyzer |
AFR | Coalescing Air Filter & Regulator | CB | Circuit Breaker |